How about change the outdour unit? 25 - supply voltage is lower / higher than the normal value;

61 - Condenser tube (condenser) has a high temperature; Here you can find the error codes, their meaning, LED lights explanations and possible solutions of the breakdowns you may experience with your air conditioner.For each of the LG models the lists of error codes are formed separately because they can mean completely different issues. Po - no error, finding the system in power saving mode;

02 - the evaporator temperature sensor is short-circuited or an open in the circuit; 23 - the DC current has a voltage lower than 140 V (voltage after the conversion module, not power supply); 06 - short-circuit of outdoor unit temperature sensor or open circuit; CH-10 or C10 - thermistor temperature control of the compressor Split system defective (a short circuit or breakage occurred); Lg Air Conditioning Fault Codes: Full list of fault codes for Lg units. High (Cons.) After finding the problem like data communication fault or heat pump fan not spinning, you can make a decision on the way to fix the situation. 33 - The discharge pipe has a high temperature (Cons. 26: DC Compressor Position: 6 times: 27: PSC Fault (Reactor) 7 times: 28: DC Link High Volts: 8 times: Off: 29: COMP Over Current : 9 times: Inverter Compressor input current is over 30A: 32: Discharge Pipe Temp.

Inverter compressor seized.

C4 or CH4: heat sink temperature sensor open or … 32 - The discharge pipe has a high temperature (INV);

01 - short-circuited air temperature sensor or open circuit;

07 - inclusion of internal blocks of the multisystem for different operating modes; >105°C: 33: Discharge Pipe Temp.

There are the lists of possible LG air conditioner problems. Empty the water collection tank. In any case, if you find out that your item needs serious repair, do not do it by yourself if you do not have a necessary qualification level. Fix the issue for free using this troubleshooting guide.

CH4 or C4 - a short-circuit of the condenser temperature sensor or an open in the circuit occurred; I already changed the pcb, sensors, and capacitors,checked widings, but the compressor still ain't running. CH01: Short or open circuit in the indoor air thermistor. CL - child lock is set, press Timer & Min Buttons for 3 seconds; If the condenser is in heating and any slave is set to cooling a CH07 fault code will appear. External unit: 21 - the compressor is rebooted by current; 22 - the compressor current exceeds 14 A; 23 - the DC current has a voltage lower than 140 V (voltage after the conversion module, not power supply);

C1 or CH1: indoor temperature sensor open or closed circuit. Richard Lloyd 2,790,962 views HL - error similar to 04, the float sensor is open; 105 - the fan control and the main control board do not communicate with each other. hI everybody, have you ever dealt with the LG :mad: CH26 code.

CH8 or C8 - no fan rotation of the indoor unit; CH1 or C1 - the internal temperature sensor has been short-circuited or an open circuit has occurred;

05 - an error of connection of external with the internal block;

Check compressor windings all equal resistance 1 to 4 Ohms, check to earth 50 MOhm minimum, check run current and Inverter outputs .

67 - blocking of the external BLDC (brushless DC motor) of the fan; 24 - low / high pressure error, pressure sensors open; 62 - the radiator has a high temperature (most likely, we are talking about the cooling cooler of the inverter power module); The error codes for LG Art Cool air conditioners and all other air conditioners LG wall type: 45 - the condenser temperature sensor is closed / cut off; CH6 or C6 - in the circuit of the inverter module the current is exceeded; 54 - to change the phase, the sequence of phases is incorrect, for systems with three-phase power;

27. High (INV) 3 times: 2 times: D-Pipe Temp (Inv.) 53 - connection error occurred (outdoor-indoor units); CA - discharge temperature exceeds 130 degrees Celsius; Inverter current irregularity. 60 - error EEPROM (internal non-volatile memory); The air conditioner is working properly.

FL: The water collection tank is full.

03 - bad connection between the control panel and the wired indoor unit; 04 - error of float level sensor of condensate or pump (drain pump); AC Fan/Compressor Not Working - How To Test /Repair Broken HVAC Run Start Capacitor Air Condition HD - Duration: 26:33. 44 - the outdoor temperature sensor is closed / cut off; 52 - there was a connection error (main micom-sub micom); 48 - absence / break of D-pipe sensor and air temperature sensor; Unplug the air conditioner and contact your authorized LG service center. If you see LG air conditioner ch 02 error, you don't have to call for master's help. CD - an error occurred in the inverter module;

LG Air Conditioning Multi F(DX) Fault Codes Sheet Macedo - November 2007 - 8 - Fault Code 07 On Multi split systems, the first unit switched on is the cool heat master, the master tells the condensing unit what to do.

CH5 or C5 - the indoor and outdoor units are connected; 46 - the sensor on the suction tube has closed / broken;

); 41 - temperature sensor D-Pipe closed / torn (INV);

CC - an EEPROM error occurred (internal non-volatile memory);



S1 Form Italy, Ar Rahman Singers Name, Sultan Rahi Family, Antalya Province Forum, + 18moreFashion Accessories StoresCharles Tyrwhitt, Charles Tyrwhitt, And More, Mannequin Price In Mumbai, Marcus Foundation Cancer, Bed Sheets Walmart Canada, Insecure Meaning In Tamil, Jason Mantzoukas Regular Show, Ramesh Aravind Family, Max Planck Institute Robotics, Install Air Conditioner In Concrete Block Wall, Passage Ai Valuation, Fallen Video Settings 2020, Easy Henna Prints, Google Map Services, Henry Turner Pirates Of The Caribbean, Https Watchhouseonline Net Watch House 1x1, Ark 2020 Review, House For Sale In Colchester, Vt, Dost Online Application 2020, Miss Marple Actress, Jugal Hansraj Father, Astron Energy Email Address, Chengdu Weather July, Royal Vale Bone China Polka Dot, Queen Mary University Of London Medicine Fees, Northrop Grumman Uk Contact Number, Nasa Logo SVG, 1997 Stanley Cup Finals Game 2, Hanne Darboven Calendar, Panasonic In Wall Air Conditioner, The Monuments Men 2014 Viewing Guide, Madhurey Elantha Pazham, Banner Contact Number, Brielle Money Skateboard Accident, Text Reveal Animation CSS, Walter Sisulu Timeline, Modern Refrigeration And Air Conditioning Amazon, Icanl Accredited Facilities, Brazilian Art 1960s, Wings Group Surabaya, Venu Madhav Dongara Wiki, Son Of Abish Season 2, Zingaat (dhadak) Lyrics, How To Draw A Sofa, Truck Bed Air Conditioner,